Operating frequency |
0.200
0.240 kHz |
Power factor λ |
0.95 |
Length |
110.0 mm |
Dimmable |
No |
Input voltage AC |
220
240 V |
Mains frequency |
50
60 Hz |
ECG efficiency |
92 % |
Inrush current |
30 A |
Max. no. of ECGs on circuit breaker 10 A |
15 |
Max. no. of ECGs on circuit breaker 16 A |
26 |
Width |
75.0 mm |
Height |
30.0 mm |
Mounting hole spacing, length |
99.0 mm |
Mounting hole spacing, width |
64.0 mm |
Cable cross-section, input side |
0.5
1.0 / 0.5
1.5 mm² |
Product weight |
245.00 g |
Cable cross-section, output side |
0.5
1.0 / 0.5
1.5 mm² |
Casing material |
Metal |
Wire preparation length, input side |
8.5
9.5 mm |
Ambient temperature range |
-15
+65 °C |
Maximum temperature at tc test point |
85 °C |
ECG lifetime |
30000 h |
Suitable for fixtures with prot. class |
I |
Overheating protection |
Power reduction and switch off at T > 85 °C at the tc point |
Max. cable length to lamp/LED module |
1.5 m |
Approval marks approval |
VDE / VDE-EMC / GOST / C-Tick |
Standards |
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 |
Type of protection |
IP20 |
U-OUT (working voltage) |
250 V |
Design / version |
Built-in unit |
EEI Energy Label |
A2 |
Input voltage range AC |
198
264 V |
Ignition voltage |
4.5 kVp |
Wire preparation length, output side |
8.5
9.5 mm |
Lamp wattage |
39 W |
Line current |
0.19 A |
System wattage |
42.50 W |
Max. no. of ECGs on 16A MCB with EBN-OS |
65 |
Max. working voltage between LH and LL |
250 V |
Protective conductor current |
0.3 mA |
Max. capacitance of wire ECG/lamp |
120 pF |
Max. working voltage betw. LL/LH & earth |
250 V |
ECG reset time |
> 0.5 s |
Restriction on ignition time |
20 min |
Electrical data
|
Operating frequency |
0.200
0.240 kHz |
Power factor λ |
0.95 |
Input voltage AC |
220
240 V |
Mains frequency |
50
60 Hz |
ECG efficiency |
92 % |
Inrush current |
45 A |
Max. no. of ECGs on circuit breaker 10 A |
7 |
Max. no. of ECGs on circuit breaker 16 A |
13 |
U-OUT (working voltage) |
250 V |
Input voltage range AC |
198
264 V |
Ignition voltage |
4.5 kVp |
Max. no. of ECGs on 16A MCB with EBN-OS |
32 |
Max. working voltage between LH and LL |
250 V |
Protective conductor current |
0.3 mA |
Max. capacitance of wire ECG/lamp |
120 pF |
Max. working voltage betw. LL/LH & earth |
250 V |
Dimensions & weight
|
Length |
110.0 mm |
Width |
75.0 mm |
Height |
30.0 mm |
Mounting hole spacing, length |
99.0 mm |
Mounting hole spacing, width |
64.0 mm |
Cable cross-section, input side |
0.5
1.0 / 0.5
1.5 mm² |
Cable cross-section, output side |
0.5
1.0 / 0.5
1.5 mm² |
Wire preparation length, input side |
8.5
9.5 mm |
Wire preparation length, output side |
8.5
9.5 mm |
Lifespan
|
ECG lifetime |
30000 h |
Additional product data
|
Design / version |
Built-in unit |
Capabilities
|
Dimmable |
No |
Suitable for fixtures with prot. class |
I |
Overheating protection |
Power reduction and switch off at T > 85 °C at the tc point |
Max. cable length to lamp/LED module |
1.5 m |
ECG reset time |
> 0.5 s |
Restriction on ignition time |
20 min |
Certificates & standards
|
Approval marks approval |
VDE / VDE-EMC / GOST / C-Tick |
Type of protection |
IP20 |
EEI Energy Label |
A2 |
Colors & materials
|
Casing material |
Metal |
Temperatures
|
Maximum temperature at tc test point |
85 °C |